[Feb 14, 2025] Ultimate D-PE-OE-23 Guide to Prepare Free Latest EMC Practice Tests Dumps [Q25-Q41]

Share

[Feb 14, 2025] Ultimate D-PE-OE-23 Guide to Prepare Free Latest EMC Practice Tests Dumps

Get Top-Rated EMC D-PE-OE-23 Exam Dumps Now

NEW QUESTION # 25
Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
- 200 TB of Fibre Channel drives on NetApp ONTAP 7
- Environment is expected to grow 200 TB over the next three years
In order to remove the encryption key on the SED drives, which steps are required?

  • A. Suspend the node and then remove the drive
  • B. Suspend the cluster and then SmartFail the drive
  • C. SmartFail and then remove the drive
  • D. SmartFail the cluster and then remove the drive

Answer: A


NEW QUESTION # 26
A server is configured with a RAID 5 Virtual Disk across 5 hard disks and 1 spare disk. If a hard disk failure occurs within the RAID 5 virtual disk, the spare disk needs to be online as quickly as possible. It is acceptable for users to experience decreased performance during the rebuild procedure.
How should this requirement met?

  • A. Select Fast Rebuild
  • B. Enable Rebuild Priority
  • C. Change cache to Write Through
  • D. Increase Rebuild Rate

Answer: D


NEW QUESTION # 27
A technician has received a new server with 5 drives and needs to configure the drives into a specific configuration as provided by the administrator.
The administrator will also add additional disks as separate raid arrays at a later date.
- Drive 0 is passed through to the OS (to be managed by the OS)
- Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5 How should the technician do this in the PERC BIOS?

  • A. Set drive 0 to Non-Raid, set drives 1-3 as a RAID 5, and drive 4 as a Dedicated Hot Spare
  • B. Set drive 0 to Ready, set drives 1-3 as a RAID 5, and drive 4 as a Global Hot Spare
  • C. Set drive 0 to Non-Raid, set drives 1-3 as a RAID 5, and drive 4 as a Global Hot Spare
  • D. Set drive 0 to Ready, set drives 1-3 as a RAID 5, and drive 4 as a Dedicated Hot Spare

Answer: A


NEW QUESTION # 28
Where is the data stored to allow Easy Restore to successfully complete a system board replacement?

  • A. Front control panel
  • B. IDSDM card
  • C. Internal USB flash
  • D. BOSS

Answer: A


NEW QUESTION # 29
A technician needs to roll back the firmware on a server for the Fiber Channel card. The technician needs to determine the previous version before rolling back the firmware.
How should the technician view the previous and current firmware versions utilizing Lifecycle Controller?

  • A. Under Hardware Configuration, select Launch Firmware Rollback and select Components
  • B. Under Firmware Update, select View Current Versions
  • C. Under Hardware Configuration, select View Current Versions
  • D. Under Firmware Update, select Launch Firmware Rollback and select Components

Answer: B


NEW QUESTION # 30
Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?

  • A. iOS devices only
  • B. iOS, Android, and Windows Phone devices
  • C. iOS and Android devices only
  • D. Android devices only

Answer: C


NEW QUESTION # 31
What could cause a PowerEdge server power supply LED to blink amber for two seconds and off for one second?

  • A. Faulted state
  • B. Mismatch voltage
  • C. Firmware update

Answer: B

Explanation:
Interpreting Power Supply LED Indicators on Dell PowerEdge Servers
Server Troubleshooting (32%)
* Analyze the visual indicators on server components - system ID, PSU, and BLINK Understanding PSU LED Blink Patterns The Power Supply Unit (PSU) on Dell PowerEdge servers uses LED indicators to communicate status information. The color and blinking pattern of the LED signify different conditions:
* Solid Green Light
* PSU is functioning normally.
* Blinking Amber Light
* Indicates a warning or fault condition.
Specific Blink Pattern:
* Blinking Amber for Two Seconds On, One Second Off
* Indicates a Mismatch Voltage Condition.
Explanation of Options
* Option A: Faulted state
* Explanation: A faulted PSU typically shows asolid amber light, not a blinking pattern.
* Conclusion: Incorrect.
* Option B: Firmware update
* Explanation: During a firmware update, the PSU LED may blink, but usually with a different pattern or color (often green).
* Conclusion: Unlikely to cause the specified blink pattern.
* Option C: Mismatch voltage
* Explanation: The blinking amber pattern of two seconds on and one second off indicates that there is a voltage mismatch between redundant power supplies or an input voltage issue.
* Possible Causes:
* PSUs of different wattages installed.
* PSUs connected to power sources with different voltages.
* One PSU not receiving power or connected to an incompatible power source.
* Conclusion:Correct Answer.
Dell Operate References
* Server Troubleshooting (32%)
* Analyze the visual indicators on server components: Understanding PSU LED indicators is essential for diagnosing power-related issues.
* System Administration (18%)
* Verify health status: Regular monitoring of server components ensures timely identification and resolution of issues.
Conclusion
A blinking amber PSU LED with a pattern of two seconds on and one second off signifies amismatch voltage condition. This requires checking the power supplies to ensure they are identical and connected to compatible power sources.


NEW QUESTION # 32
What is the minimum number of components, beside the system board, required to POST?

  • A. PSUs, CPUs, and DIMMs as configured in BIOS
  • B. 1 PSU, 1 DIMM, and 1 CPU only
  • C. 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controller
  • D. 1 PSU and 1 CPU only

Answer: B


NEW QUESTION # 33
A technician needs to configure a server to PXE boot a server setup image with the BIOS in UEFI mode.
Which two steps should the technician perform to enable this function? (Choose two.)

  • A. Boot to Ctrl+S and configure the NIC for PXE Device1.
  • B. Navigate to Boot Options Settings and set PXE Device1 as first option.
  • C. From System Setup Utility, choose Device Settings. Configure NIC for PXE.
  • D. From the iDRAC web interface, select Network Settings, and enable PXE Device1.
  • E. Navigate to Network Settings, PXE Device1 Settings, and configure IP.

Answer: A,B


NEW QUESTION # 34
A technician receives a new server with five drives.
They need to configure the drives based on the following requirements received from the administrator:
- Drive 0 as a single disk with no RAID
- Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5 The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.
How should the technician configure the drives?

  • A. Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare
  • B. Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
  • C. Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare
  • D. Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

Answer: D


NEW QUESTION # 35
What type of fans are installed in servers with NVMe storage and GPU configurations?

  • A. STD
  • B. LFM
  • C. VHP
  • D. HPR

Answer: C


NEW QUESTION # 36
Refer to the exhibit.

A technician is testing basic SMTP alerts on an iDRAC for a server. The test SMTP alerts fail with the message shown. The technician can ping the hostname of the SMTP server from their workstation.
Which two actions should the technician take to fix the issue? (Choose two.)

  • A. Verify SMTP port settings on the iDRAC
  • B. Add iDRAC hostname to the SMTP server hosts file
  • C. Use the IP address of the SMTP server
  • D. Enable the SMTP Client service on the iDRAC

Answer: A,C


NEW QUESTION # 37
An engineer needs to upgrade a Dell EMC PowerEdge R440 server from a single PSU to dual PSU configuration. There are unused PSU modules from PowerEdge R430 and R420 servers available, and they have the same wattage ratings.
What should the engineer do to complete the task?

  • A. Add the PowerEdge R430 PSU modules to the PowerEdge R440
  • B. Add the PowerEdge R420 PSU modules to the PowerEdge R440
  • C. Order a new PSU specific to the existing PowerEdge R440
  • D. Configure the PowerEdge R440 PSU with 1+1 configuration

Answer: C


NEW QUESTION # 38
A technician in Portland, Oregon has been asked to update the firmware on a server in Omaha, Nebraska. They will use an NFS server also located in Nebraska for serving patches that have been vetted by their security teams.
What two pieces of information does the technician need in order to access the NFS patch server from the Lifecycle Controller or iDRAC? (Choose two.)

  • A. IP address or hostname
  • B. CHAP authentication credentials
  • C. Username and password
  • D. Share name

Answer: C,D


NEW QUESTION # 39
Which front disk chassis option is available in a Dell EMC PowerEdge R740 server?

  • A. 12x 2.5" drives
  • B. 4x 3.5" drives
  • C. 24x 2.5" drives
  • D. 8x 3.5" drives

Answer: D


NEW QUESTION # 40
A technician configures iDRAC on a new server for access on the management network. When accessing via telnet, the connection is refused. Network connectivity is a verified network. NO ports are blocked by any network devices.
Why is the telnet connection being refused?

  • A. The iDRAC must be configured to allow the IP address of the technician's workstation.
  • B. Telnet is NOT supported to access iDRAC.
  • C. Telnet is NOT enabled by default on the iDRAC
  • D. The telnet client must be configured to connect to port 8899 on the iDRAC

Answer: C


NEW QUESTION # 41
......


EMC D-PE-OE-23 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Server Portfolio and Features: This section of the exam measures the skills of Dell System Administrators and Dell Technical Support Engineers and covers the definitions of chassis form factors and their numbering systems.
Topic 2
  • System Administration: This section of the exam measures the skills of Dell System Administrators and covers verifying health status and managing iDRAC licenses.
Topic 3
  • Server Management and Configuration Tools: This section of the exam measures the skills of Dell Technical Support Engineers and covers the functions of iDRAC, including login procedures and connection methods. It explains various management interface options like LCC and racadm, as well as in-band and out-of-band management techniques.
Topic 4
  • Server Components: This section of the exam measures the skills of Dell System Administrators and covers various server components, including processors, memory options, and configurations. It also addresses power options, redundancy features, thermal management, and liquid cooling systems.
Topic 5
  • Server Troubleshooting: This section of the exam measures the skills of Dell Technical Support Engineers and covers analyzing visual indicators on server components such as system IDs and power supply units.

 

Passing Key To Getting D-PE-OE-23 Certified Exam Engine PDF: https://actualtests.real4prep.com/D-PE-OE-23-exam.html